Login/Register
Toggle navigation
Home
Community
Knowledge
Technical Docs
RWS Support Policy
Trados Studio Licensing Help
Login for Support
Error message when confirming segment in Studio 2019 SR2 15.2.4.1693 (CU4): Value cannot be null. Parameter name: baseUrl
Article Number:
000011647
|
Last Updated:
2/6/2020 10:28 PM
Scope/Environment
SDL Trados Studio 2019 SR2 15.2.4.1693 (CU4)
Symptoms/Context
When you try to confirm a segment in Studio 2019 SR2 15.2.4.1693 (CU4) the error message is displayed:
Resolution
Reset non project-related settings:
Close all SDL applications.
Go to the following folder:
SDL Trados Studio 2019:
Windows 7/8/10
:
C:\Users\%USERNAME%\AppData\Roaming\SDL\SDL Trados Studio\15.0.0.0
NOTE:
If you do not find this folder, make sure that these files are not hidden. See KB article
Showing hidden files, folders and extensions on Windows operating systems
Rename the following XML files (for example, add an underscore before/after the file name):
BaseSettings.xml
Plugincache.xml
UserSettings.xml
Restart Studio.
Workaround 3: Reset SDL Trados Studio to default settings (
in addition to Workaround 2
)
Follow the steps from KB article
Resetting SDL Trados Studio to default state
Root Cause
User settings corrupted by one of the out-dated plugins.
Reference
The issue was no longer reproducible in Studio 2019 SR2 CU5 (15.2.5.2145).
Download link:
ftp://sdlpatches:5dlpatch35@ftp-emea.sdlproducts.com/SDL_TP/Studio2019_CUs/SDLTradosStudio2019_SR2_CU5_2145.zip
Send Article Feedback